Study of neutron response for two hybrid RPC setups using the GEANT4 MC simulation approach

The present article describes a detailed neutron simulation study in the energy range 10~(-10) MeV to 1.0 GeV for two different RPC configurations.The simulation studies were taken by using the GEANT4 MC code.Aluminum was utilized on the GND and readout strips for the (a) Bakelite-based and (b) glass-based RPCs.For the former type of RPC setup the neutron sensitivity for the isotropic source was S_n=2.702×10~(-2) at E_n=1.0 GeV, while for the latter type of RPC, the neutron sensitivity for the same source was evaluated as S_n=4.049×10~(-2) at E_n=1.0 geV.These results were further compared with the previous RPC configuration in which copper was used for ground and pickup pads.Additionally A1 was employed at (GND+strips) of the phosphate glass RPC setup and compared with the copper-based phosphate glass RPC.Good agreement with sensitivity values was obtained with the current and previous simulation results.

作 者: M.Jamil J.T.Rhee Y.J.Jeon   作者单位: M.Jamil(Institute for Advanced Physics,Konkuk University,Seoul 143-701,Korea;Liquid Crystal Research Center,Konkuk University,Seoul 143-701,Korea)

J.T.Rhee(Institute for Advanced Physics,Konkuk University,Seoul 143-701,Korea)

Y.J.Jeon(Liquid Crystal Research Center,Konkuk University,Seoul 143-701,Korea) 

刊 名: 中国物理C(英文版)  ISTIC 英文刊名: CHINESE PHYSICS C  年,卷(期): 2009 33(10)  分类号: O4  关键词: resistive plate chambers   neutron sensitivity   GEANT4   Monte Carlo simulation